Vue d'ensemble
As a leading high-voltage electrical equipment supplier, Chuanli Electric delivers the 10kV/20kV/24kV SC(B)13, SC(B)14, and SC(B)18 epoxy cast resin dry-type transformers. Engineered for high-density urban power grids, data centers, and heavy industrial facilities, these units serve as the ideal eco-friendly alternative to traditional oil-immersed distribution transformers. Whether you are an EPC contractor or an industrial utility manager, our cast resin transformers guarantee peak operational reliability, meeting strict international IEC standards for high-voltage distribution networks.
Signification du modèle
| S | C | (B) | □ | – | □ | / | □ |
| ↓ | ↓ | ↓ | ↓ | | ↓ | | ↓ |
| Triphasé | Isolation en résine | Feuille basse tension
enroulement | Niveau de performance
Nom de code | | Capacité nominale
(KVA) | | Niveau de tension
(KV) |
Caractéristiques du produit
Les transformateurs de puissance 10/20/24kV SC(B)13/14/18 produits par notre usine sont des transformateurs de type sec avec bobine enroulée en résine à faible bruit et à faible perte avec certificat de type de produit. Grâce à une conception avancée, des matériaux de haute qualité, une formulation scientifique, un processus strict et des normes de test élevées, les produits présentent les caractéristiques suivantes :
L'enroulement haute tension du fil de cuivre, l'enroulement basse tension du fil de cuivre ou de la feuille de cuivre, le mat de fibre de verre est rempli d'emballage, l'emballage sous vide de l'époxy utilisé sans coulée, le durcissement pour former un solide cylindrique dans son ensemble, la résistance mécanique élevée, la décharge partielle faible, la fiabilité élevée.
Antiflamme, anti-explosion, ne pollue pas l'environnement. La bobine d'enroulement en fibre de verre possède des propriétés d'auto-extinction et ne produit pas d'arc électrique en cas de court-circuit, ni de gaz toxiques ou nocifs à haute température.
La bobine n'absorbe pas l'humidité, les pinces du noyau ont une couche spéciale de protection contre la corrosion, 100% humidité relative et autres environnements difficiles. La conduite interrompue n'a pas besoin d'enlever le traitement de la marée.
Résistance aux courts-circuits et haut niveau d'impulsion d'allumage.
La résine à l'intérieur et à l'extérieur du serpentin est fine, la dispersion de la chaleur est bonne. L'air de refroidissement est utilisé pour refroidir l'air (AN). Pour tous les degrés de protection, le transformateur est équipé d'un système de refroidissement par air (AF), afin d'améliorer la capacité de surcharge à court terme et d'assurer un fonctionnement sûr.
Consommation réduite, économie d'énergie. Fonctionne pour une économie, peut être sans entretien.
Petit volume, poids léger, petite surface, coûts d'installation réduits, pas besoin de réservoir d'huile, protection contre les incendies et alimentation de secours, onduleur de secours.
Comme il n'y a pas de risque d'incendie ou d'explosion, le centre de charge peut être réparti et installé à proximité du point d'alimentation, ce qui permet de réduire le coût de la ligne et d'économiser les frais d'installation coûteux.
SC (B) 13 Transformateur à sec
| Type | Classé Capacité (KVA) | Combinaisons de tension et plage de prise | Connexion symbole du groupe | Sans charge perte (W) | Perte de charge 75℃ (W) | Sans charge actuel (%) | Court-circuit impédance (%) |
Haute pression (kV) | Haute pression plage de prise (%) | Basse pression (kV) |
| SC(B)13-30 | 30 | 24
20
10
6.3
6 | ±5%
±2×2.5
/
×2.5
+3
-1 | 0.4 | Yyn0
/
Dyn11 | 135 | 640 | 2.0 | 4.0 |
| SC(B)13-50 | 50 | 195 | 900 | 2.0 |
| SC(B)13-80 | 80 | 265 | 1240 | 1.5 |
| SC(B)13-100 | 100 | 290 | 1410 | 1.5 |
| SC(B)13-125 | 125 | 340 | 1660 | 1.3 |
| SC(B)13-160 | 160 | 385 | 1910 | 1.3 |
| SC(B)13-200 | 200 | 445 | 2270 | 1.1 |
| SC(B)13-250 | 250 | 515 | 2480 | 1.1 |
| SC(B)13-315 | 315 | 635 | 3120 | 1.0 |
| SC(B)13-400 | 400 | 705 | 3590 | 1.0 |
| SC(B)13-500 | 500 | 835 | 4390 | 1.0 |
| SC(B)13-630 | 630 | 965 | 5290 | 0.85 |
| SC(B)13-630 | 630 | 935 | 5360 | 0.85 | 6.0 |
| SC(B)13-800 | 800 | 1090 | 6260 | 0.85 |
| SC(B)13-1000 | 1000 | 1270 | 7310 | 0.85 |
| SC(B)13-1250 | 1250 | 1500 | 8720 | 0.85 |
| SC(B)13-1600 | 1600 | 1760 | 10500 | 0.85 |
| SC(B)13-2000 | 2000 | 2190 | 13000 | 0.7 |
| SC(B)13-2500 | 2500 | 2590 | 15400 | 0.7 |
SCB14 Dry Change Niveau 2 Efficacité énergétique
| Capacité nominale (kVA) | Perte à vide (W | Perte de charge (W) | Courant à vide (%) | Dimensions (mm) |
| 30 | 130 | 640 | 2.0% | 700*360*675 |
| 50 | 180 | 900 | 2.0% | 770*460*710 |
| 80 | 250 | 1240 | 1.5% | 770*460*770 |
| 100 | 270 | 1415 | 1.3% | 790*460*730 |
| 125 | 320 | 1665 | 1.3% | 870*460*845 |
| 160 | 365 | 1915 | 1.1% | 860*460*805 |
| 200 | 420 | 2275 | 1.1% | 940*920*806 |
| 250 | 490 | 2485 | 1.0% | 960*920*906 |
| 315 | 600 | 3125 | 1.0% | 980*970*906 |
| 400 | 665 | 3590 | 1.0% | 1010*970*936 |
| 500 | 790 | 4390 | 1.0% | 1030*970*956 |
| 630 | 885 | 5360 | 0.9% | 1220*1120*906 |
| 800 | 1035 | 6265 | 0.9% | 1270*1170*946 |
| 1000 | 1205 | 7315 | 0.9% | 1300*117*1016 |
| 1250 | 1420 | 8720 | 0.9% | 1370*1220*1051 |
| 1600 | 1665 | 10555 | 0.9% | 1450*1270*1161 |
| 2000 | 2075 | 13005 | 0.7% | 1470*1270*1295 |
| 2500 | 2450 | 15445 | 0.7% | 1450*1320*1336 |
SCB18 Dry Change Niveau 1 Efficacité énergétique
| Capacité nominale (kVA) | Perte à vide (W) | Perte de charge (W) | Courant à vide (%) | Dimensions (mm) |
| 30 | 130 | 640 | 2.0% | 700*360*675 |
| 50 | 185 | 900 | 2.0% | 770*460*710 |
| 80 | 250 | 1240 | 1.5% | 770*460*770 |
| 100 | 270 | 1415 | 1.3% | 790*460*730 |
| 125 | 320 | 1665 | 1.3% | 870*460*845 |
| 160 | 365 | 1915 | 1.1% | 860*460*805 |
| 200 | 420 | 2275 | 1.1% | 940*920*806 |
| 250 | 490 | 2485 | 1.0% | 960*920*856 |
| 315 | 510 | 3125 | 1.0% | 980*970*906 |
| 400 | 570 | 3590 | 1.0% | 1010*970*936 |
| 500 | 670 | 4390 | 1.0% | 1030*970*956 |
| 630 | 750 | 5365 | 0.9% | 1220*1120*906 |
| 800 | 875 | 6265 | 0.9% | 1270*1170*946 |
| 1000 | 1020 | 7315 | 0.9% | 1300*1170*1016 |
| 1250 | 1205 | 8720 | 0.9% | 1370*1220*1051 |
| 1600 | 1415 | 10555 | 0.9% | 1450*1270*1161 |
| 2000 | 1760 | 13005 | 0.7% | 1475*1270*1295 |
| 2500 | 2080 | 15445 | 0.7% | 1450*1320*1356 |
Complete B2B Power Distribution Solutions
To ensure grid stability and compliance with global energy regulations, choosing between Tier 1 and Tier 2 energy efficiency is critical. For instance, our SCB18 series delivers Tier 1 eco-design efficiency, significantly lowering long-term operational costs in large-scale solar projects and infrastructure.
When designing a turnkey distribution substation, a dry-type transformer must operate seamlessly with upstream and downstream high-voltage protection devices:
1. Upstream Protection: Learn more about selecting the right grid breakers in our technical guide on Principaux éléments d'une armoire électrique.
2. Photovoltaic & Renewable Integration: If you are engineering for clean energy plants, discover How to Adapt Prefabricated Switchgear to the High-Voltage Distribution Requirements of 10kv Photovoltaic Power Plants.
3. System Maintenance: Avoid costly downtime by reviewing our professional guide on Power Transformer Repair: How to Identify Repairable vs Non-Repairable Faults.
FAQ about SC(B) 13/14/18 Dry-Type Transformers
1. What is the main difference between SCB13, SCB14, and SCB18 dry transformers?
The primary difference lies in their energy efficiency levels and core loss reduction. Our SCB18 series meets Level 1 energy efficiency standards, reducing no-load losses by up to 20-25% compared to the SCB13, which translates to massive long-term operational savings for your project.
2. Can your resin-insulated dry transformers operate in 100% humidity?
Yes, absolutely. Because our copper/foil windings are completely encapsulated in vacuum-cast epoxy resin, the coils do not absorb moisture. You can safely deploy them in 100% relative humidity and harsh environments without any pre-drying or “tide treatment” after idle periods.
3. Why should I choose a cast resin transformer over an oil-immersed transformer?
Cast resin transformers offer superior fire and explosion safety (self-extinguishing glass fiber insulation), making them ideal for high-density indoor spaces like subways, hospitals, and commercial centers. Additionally, you eliminate oil leakage risks, rendering them virtually maintenance-free.
4. What cooling options are available for your power transformers?
We provide two operational modes: Natural Air Cooling (AN) for standard, continuous load operations, and Forced Air Cooling (AF). With our integrated AF cooling system, you can increase the short-term overload capacity of your transformer by up to 40-50% for peak safety.
5. Do you provide custom voltage combinations and tap ranges?
Yes, we design for your specific grid matrix. Our standard line supports high voltage ratings of 6.3kV, 10kV, 20kV, and 24kV with tap ranges of ±5% or ±2×2.5%, stepping down to a low voltage of 0.4kV with standard Dyn11 or Yyn0 connection groups.