Visión general
When your turnkey project requires a low-profile, highly secure outdoor power solution, our three-phase pad-mounted transformer delivers industrial-grade performance directly to your site. Engineered specifically for underground distribution systems, Clelek provides you with highly customizable units ranging from 45 kVA to 5000 kVA, with primary voltages up to 34.5 kV. As a dedicated pad-mounted transformer manufacturer with 20 years of North American market experience, we ensure every liquid-filled unit streamlines your commercial power distribution network with maximum efficiency and zero safety compromise.
Características principales
● Construcción robusta: Carcasas de acero de calibre grueso con acabado horneado con recubrimiento en polvo para una resistencia a la manipulación y una durabilidad a prueba de intemperie.
● Configuraciones flexibles: Disponible en diseños de frente vivo y frente muerto, compatible con aplicaciones radiales o de alimentación en bucle.
● Tecnología Eco-Safe: Relleno de fluido dieléctrico biodegradable sostenible para una protección fi ja superior y una mayor vida útil.
Aplicaciones primarias
● Servicios públicos: Soluciones de transformadores reductores
● Minería de Bitcoin: Transformadores del lado de carga especializados de 415 V (configuración en Y).
● Huertas solares: Sistemas de transformadores elevadores
● Industrial: Adecuado para entornos exigentes, incluidas ubicaciones peligrosas
Ventajas técnicas
● 20 años de experiencia en el mercado norteamericano
● Línea completa de productos de transformadores de distribución montados en pedestal con alimentación líquida.
● Cumplimiento de las estrictas normas operativas norteamericanas.
● Soluciones de ingeniería personalizadas disponibles
Cobertura de servicios
Proporcionamos soluciones profesionales en transformadores para los sectores de servicios públicos, energías renovables e industrial en toda Norteamérica.
Tipos de fluidos aislantes
Los transformadores sumergidos en líquido suelen utilizarse en el exterior debido a la preocupación que suscitan los derrames de aceite o los incendios si el aceite alcanza su punto de inflamación. Recientemente, se han desarrollado nuevos líquidos aislantes (por ejemplo, fluido de silicona, FR3) con una temperatura de punto de inflamación superior a la del aceite mineral, y los transformadores con estos líquidos pueden utilizarse en interiores. Sin embargo, es importante señalar que estos transformadores sumergidos en líquidos menos inflamables tienen unos costes iniciales más elevados que sus homólogos de tipo seco, lo que impide su adopción generalizada en el mercado.
Para aplicaciones de transformadores, la silicona es ideal por su estabilidad térmica, compatibilidad de materiales, baja inflamabilidad y baja toxicidad. El alto punto de inflamación de la silicona, de 340 ºC, la convierte en un fluido menos inflamable que cuenta con la certificación UL y la aprobación mutua de fábrica para aplicaciones interiores y exteriores. Es ideal en lugares con riesgo de incendio y con sistemas especiales de extinción de incendios.
El fluido dieléctrico FR3 es totalmente biodegradable y respetuoso con el medio ambiente. Es adecuado para su uso en interiores y en zonas con alta sensibilidad medioambiental donde cualquier derrame de fluido aislante podría requerir una limpieza exhaustiva.
Dimensiones mínimas y específicas
Hay dos confi guraciones para el diseño del frente muerto: dimensiones mínimas y dimensiones específi cas. Las dimensiones mínimas abarcan la separación mínima entre casquillos, la altura de los casquillos y la profundidad del compartimento. En cambio, las dimensiones específicas abarcan dimensiones distintas de las mínimas, teniendo en cuenta las instalaciones, el mantenimiento y la facilidad de conexión.
Características estándar de un transformador tipo pedestal

| Número de serie |
Nombre |
| 1 |
Ganchos de elevación |
| 2 |
Compartimento de terminales con umbral delantero extraíble |
| 3 |
Puertas de armario abatibles y elevables |
| 4 |
Mango de candado de cabeza pentagonal entrelazada |
| 5 |
Placas de masa (no mostradas) |
| 6 |
Barreras de compartimentos |
| 7 |
Placa de características |
| 8 |
Dispositivo de descarga de presión |
| 9 |
Cambiador de tomas |
| 10 |
Válvula de drenaje |
| 11 |
Correa de tierra desmontable |
| 12 |
Pozos de buje (para diseño de frente muerto) |
| 13 |
Bujes de pala (para diseño de frente vivo) |
| 14 |
Puestos de estacionamiento |
| 15 |
Terminales de pala |
| 16 |
Interruptor-seccionador |
| 17 |
Fusible Bay-O-Net |
| 18 |
Indicador de nivel de líquido |
S22M Aceite a nivel 1 Eficiencia energética
| Capacidad nominal
(kVA) |
Tensión primaria
(V) |
Tensión secundaria
(V) |
Gama de tomas de alta tensión |
Impedancia
Porcentaje(%Z) |
Tensión nominal de línea:
Estándar BIL(KV) |
Certificaciones |
| 45 |
440V-35.000V |
208/120Y-34.500V |
2×±2,5% |
2.70-5.75 |
1,2KV:30KV
2,5KV:45KV
5,0kV:60KV
8,7KV:75KV
15KV:95KV
25kV:125/150KV
34,5kV:150KV |
UL/C-UL |
| 75 |
2×±2,5% |
2.70-5.75 |
UL/C-UL |
| 112.5 |
2×±2,5% |
3.10-5.75 |
UL/C-UL |
| 150 |
2×±2,5% |
3.10-5.75 |
UL/C-UL |
| 225-300 |
2×±2,5% |
3.10-5.75 |
UL/C-UL |
| 500 |
2×±2,5% |
4.35-5.75 |
UL/C-UL |
| 750-10,000 |
2×±2,5% |
5.75-6.50 |
UL/C-UL |
Dimensiones del diseño

Transformador de montaje en pedestal-Dimensiones en pulgadas (mm)
| kVA |
A |
B |
C |
D |
E |
F |
I |
Galones |
Aproximadamente
Peso |
DOE 2016
Eficacia |
| 45 |
50 |
68 |
39 |
42 |
26 |
68 |
20 |
115 |
2150 |
0.9892 |
| 75 |
50 |
68 |
39 |
42 |
26 |
68 |
20 |
125 |
2350 |
0.9903 |
| 112.5 |
50 |
68 |
39 |
42 |
26 |
68 |
20 |
135 |
2600 |
0.9911 |
| 150 |
50 |
68 |
49 |
42 |
26 |
68 |
20 |
150 |
2900 |
0.9916 |
| 225 |
50 |
72 |
53 |
42 |
30 |
72 |
20 |
170 |
3400 |
0.9923 |
| 300 |
50 |
72 |
55 |
42 |
30 |
72 |
20 |
190 |
3950 |
0.9927 |
| 500 |
50 |
72 |
61 |
42 |
30 |
72 |
20 |
240 |
5300 |
0.9935 |
| 750 |
64 |
72 |
63 |
42 |
30 |
72 |
20 |
300 |
7150 |
0.994 |
| 1000 |
64 |
72 |
64 |
42 |
30 |
72 |
20 |
350 |
8950 |
0.9943 |
| 1500 |
73 |
89 |
71 |
42 |
30 |
72 |
24 |
400 |
11450 |
0.9948 |
| 2000 |
73 |
101 |
75 |
42 |
30 |
72 |
24 |
525 |
13800 |
0.9951 |
| 2500 |
73 |
101 |
99 |
42 |
30 |
72 |
24 |
600 |
16750 |
0.9953 |
Nota: Las dimensiones de referencia de esta tabla cubren lo siguiente: configuraciones de frente vivo y frente muerto, alimentación por bucle y alimentación radial, unidades rellenas de aceite mineral y FR3.
Variaciones dimensionales
Variaciones de altura
1. Añada 9,00 pulgadas (228,6 mm) a la altura cuando utilice fusibles de bayoneta en todas las potencias en kVA.
2. El fluido de éter natural, menos inflamable, requiere depósitos más profundos en algunas potencias de transformador.
3. Añada 50,8 mm (2,00 pulgadas) a la profundidad de los valores kVA 75-1500. Añada 8,00 pulgadas (203,2 mm) a la profundidad de los valores nominales de kVA 2000 y 2500.
Integrating Pad-Mounted Transformers Into Your Distribution Substation
Building a resilient medium-voltage network requires seamless synchronization between your outdoor transformers and indoor switchgear control rooms:
PREGUNTAS FRECUENTES
1: What is the capacity range and efficiency standard of Clelek’s three-phase pad-mounted transformers?
Our three-phase pad-mounted transformers cover a wide rated capacity range from 45 kVA up to 2500 kVA (and custom solutions up to 5000 kVA). Every unit in this product line is meticulously engineered to meet DOE 2016 energy efficiency standards, ensuring minimal core losses and lower long-term operational costs for your utility network.
2: Can I choose eco-friendly insulating fluids for indoor or environmentally sensitive installations?
Yes, you can. While standard mineral oil is highly cost-effective for typical outdoor commercial power distribution, we offer premium FR3 dielectric fluid and silicone fluid options. With high fire points (FR3 and silicone reach over 300°C and 340°C respectively), these less-flammable, fully biodegradable liquids are UL Listed and Factory Mutual approved, making them ideal for your indoor layouts or zero-tolerance eco-sensitive areas.
3: What is the structural difference between minimum dimensions and specific dimensions in your deadfront design?
When you specify a deadfront design for your project, we offer two layout configurations. Minimum dimensions strictly cover the mandatory clearance requirements, including standard bushing spacing, bushing height, and primary compartment depth. In contrast, specific dimensions extend beyond the bare minimums to give your field technicians extra spatial clearance for easier cable connection, safer routine maintenance, and smoother tool maneuvering.
4: Do your transformers support customized configurations for Bitcoin mining and renewable energy?
Absolutely. We possess extensive experience tailoring units for demanding environments. For crypto mining infrastructure, we provide specialized 415V (Y-configuration) load-side transformers optimized for high harmonic loads. For solar farms and wind plants, we engineer heavy-duty step-up transformer systems designed to withstand the cyclic power fluctuations typical of renewable energy generation.
5: What technical details should I provide to get a wholesale B2B quote from Clelek?
To ensure our engineering team delivers an accurate quotation and lead time within 24 hours, please submit your required kVA rating (e.g., 500 kVA, 750 kVA), primary voltage (up to 34.5 kV), secondary voltage (e.g., 208Y/120V, 480Y/277V), feed layout (Loop feed or Radial feed), and front configuration (Dead-front or Live-front). Contact our North American support desk to initiate your custom engineering request.