Dry-Type vs Oil-Immersed Transformer: How to Choose for Indoor, Industrial & Solar Projects

19/10/2026

Choosing between a dry type transformer and an oil immersed transformer is one of the first — and most expensive — decisions in any medium voltage project. The right answer depends on where the unit will be installed, what load it will serve, and how much maintenance your team can realistically perform. This transformer selection guide compares both technologies across fire safety, cost, efficiency and maintenance, then applies the comparison to three common scenarios: indoor commercial buildings, industrial plants, and utility-scale solar projects.

What Is the Difference Between a Dry-Type and an Oil-Immersed Transformer?

A dry type transformer uses epoxy resin or vacuum pressure impregnated (VPI) insulation, with air as the cooling medium — no liquid at all. In cast resin transformer designs, the windings are fully encapsulated in flame-retardant, self-extinguishing epoxy. Known in French-speaking markets as transformateur sec and in Spanish-speaking markets as transformador seco, these units are the default choice wherever fire safety and low maintenance come first.

An oil immersed transformer (also specified as an oil cooled transformer or liquid-filled transformer) surrounds its windings with mineral oil, which simultaneously insulates the conductors and transfers heat to the tank wall and radiator fins. Chuanli Electric manufactures both technologies — you can browse the full power transformer range for rated capacities, voltage classes and datasheets.

SCB13/14/18 epoxy resin cast resin dry type transformer (10/20/24 kV) manufactured by Chuanli Electric

Dry-Type (Cast Resin) Transformers: Strengths and Trade-Offs

Chuanli Electric’s SC(B)13/14/18 series epoxy cast resin transformer line covers 10 kV, 20 kV and 24 kV grades with rated capacities from 30 kVA up to 2,500 kVA. The high-voltage winding uses copper wire and the low-voltage winding uses copper foil, encapsulated in glass-fibre-reinforced resin. Because the coil does not absorb moisture and the core clamps carry a special corrosion-protection layer, these units operate reliably even at 100% relative humidity.

  • Fire safety: no flammable liquid, no toxic or harmful gases released at high temperature — ideal inside buildings and tunnels.
  • Virtually maintenance-free: no oil sampling, no DGA testing, no leak inspection; periodic cleaning and visual checks are enough.
  • Efficiency: the SCB18 series meets Level 1 energy efficiency, cutting no-load losses by 20–25% compared with SCB13 — a decisive factor over a 20-year service life.
  • Cooling flexibility: Natural Air cooling (AN) for continuous loads, with optional Forced Air cooling (AF) to boost short-term overload capacity.

The trade-offs: cast resin units cost more per kVA than liquid-filled equivalents, and outdoor installation requires a protective IP-rated enclosure because the resin surface is not designed for direct weather exposure.

Explore the SC(B)13/14/18 resin-insulated dry type transformer specifications, including the full no-load and load loss tables for each efficiency level.

Oil-Immersed (Oil-Cooled) Transformers: Strengths and Trade-Offs

An oil immersed transformer remains the most economical way to move serious power outdoors. Chuanli Electric’s fully sealed 6–24 kV and 35 kV oil-immersed units are built to GB 1094 and GB/T 6451, fully compatible with IEC 60076, with CE certification available for export projects. The corrugated fin tank provides both cooling and a “breathing” function that keeps the oil sealed against moisture across a −25°C to +40°C ambient range.

  • Cooling classes: ONAN (Oil Natural Air Natural) as standard, with optional ONAF fans for higher continuous capacity.
  • Built-in protection: pressure release valves on 30–2,000 kVA units, gas alarm and trip relays, and oil temperature measurement on request.
  • Environmental tolerance: pollution degree Class III, wind resistance up to 35 m/s, and anti-corrosion painting for coastal or industrial atmospheres.
  • Voltage coverage: from 6 kV distribution up to 35 kV sub-transmission, with on-load tap changer (OLTC) options such as the SZ11 series.

The trade-offs: mineral oil is combustible, so indoor installation demands a dedicated transformer room with oil containment and fire protection; and the units require periodic oil sampling and dissolved gas analysis (DGA) as part of a preventive maintenance program.

See the 6–24 kV oil immersed transformer datasheet for cooling classes, protection devices and operating conditions.

Fully sealed 35 kV oil immersed power transformer with corrugated fin tank and conservator, manufactured by Chuanli Electric

Dry Type vs Oil Immersed: Side-by-Side Comparison

Selection Factor Dry-Type (Cast Resin) Oil-Immersed
Insulation & cooling Epoxy resin / air (AN, optional AF) Mineral oil (ONAN, optional ONAF)
Fire risk Very low — self-extinguishing resin Combustible oil; containment required
Indoor installation Direct, next to the load Dedicated transformer room / vault
Maintenance Minimal — visual checks, cleaning Oil sampling, DGA, seal inspection
Typical ratings 10/20/24 kV, 30–2,500 kVA 6–35 kV, up to utility substation sizes
Efficiency benchmark SCB18: Level 1, no-load loss −20–25% vs SCB13 Low-loss designs per GB/T 6451
Upfront cost per kVA Higher Lower
Best suited for Indoor, commercial, tunnels, clean processes Outdoor, industrial, solar, utilities

Transformer Selection Guide by Project Type

Indoor & Commercial Buildings

For shopping centres, hospitals, data centres, offices and metro systems, the dry type transformer is almost always the correct answer. Fire codes in most jurisdictions either prohibit or severely restrict bulk mineral oil inside occupied buildings, while a cast resin unit can sit in a ventilated electrical room directly beside the load — shorter low-voltage cable runs, lower I²R losses, and no oil containment pit to build. Specify an IP3X or IP4X enclosure and confirm ambient temperature and altitude against the nameplate ratings before ordering.

Industrial Plants & Utilities

For petrochemical, metallurgy, mining and utility distribution, the oil immersed transformer wins on cost per kVA, overload tolerance and environmental robustness. Outdoor placement eliminates the fire-protection burden, and corrugated-fin sealed tanks shrug off dust, pollution degree Class III atmospheres and coastal corrosion. For heavier industrial loads at 35 kV, specify an on-load tap changer to hold voltage stable across shifting process loads. The exception is clean production — food, pharmaceutical and electronics plants often still prefer dry-type units inside the process building and oil-filled units only at the incoming substation.

Solar Farms & Renewable Projects

Utility-scale solar combines both technologies. At the inverter stations, indoor cast resin transformer units sit inside the skid or container, close to the inverters where their fire safety and maintenance-free operation matter most. For the medium-voltage collection system, outdoor oil immersed transformer units in pad-mounted or compact substation format step voltage up from roughly 0.8 kV to 35 kV for the collector grid. A hermetically sealed, low-loss pad-mounted design minimises the losses that compound across 25 years of daily generation cycles.

Three-phase pad-mounted oil immersed transformer for solar farm and underground distribution networks

Chuanli Electric supplies dedicated outdoor units for these applications — review the three-phase pad-mounted transformer designed for solar collector systems and underground network distribution.

Not Sure Which Transformer Fits Your Project?

Send us your load profile, primary/secondary voltage and installation environment. Our engineers — suppliers to China’s State Grid on projects including the Three Gorges and West–East Power Transmission programs — will recommend the optimal dry-type or oil-immersed solution with a complete loss table and quotation within 24 hours.

Get Expert Transformer Selection Advice

Total Cost of Ownership: Look Beyond the Purchase Price

Purchase price is only the entry point of the dry type vs oil immersed decision. Three cost layers sit behind it:

  • Energy losses: over a 20-year life, no-load losses run 24/7. Stepping up from SCB13 to SCB18 (Level 1 efficiency) cuts no-load losses by 20–25%, which frequently repays the price premium within a few years at commercial electricity tariffs.
  • Maintenance and fire protection: oil-filled units need annual oil sampling and DGA, plus containment and fire suppression indoors. Cast resin units need almost nothing — but their higher purchase price must be weighed against these avoided costs.
  • Downtime and compliance: an oil leak or failed DGA test takes a transformer out of service for weeks. Dry-type failures are rarer in clean, ventilated rooms, and compliance inspections are simpler.

Frequently Asked Questions

Which transformer type is safer for indoor installation?

Dry-type (cast resin) transformers. They contain no flammable liquid and release no toxic gases at high temperature, so they can be installed in an electrical room next to the load. An oil immersed transformer indoors requires a dedicated transformer vault with oil containment and fire protection under most fire codes.

What do ONAN and ONAF cooling classes mean?

ONAN (Oil Natural Air Natural) means oil circulates by natural convection and the tank dissipates heat naturally — the standard rating of an oil immersed transformer. ONAF (Oil Natural Air Forced) adds fans to increase the continuous rating by roughly 25–50% on the same tank.

Which is more efficient, dry type or oil immersed?

Both technologies offer low-loss designs; the efficiency class matters more than the cooling medium. Chuanli Electric’s SCB18 cast resin series reaches Level 1 energy efficiency with 20–25% lower no-load losses than SCB13, and the oil-immersed range is built to low-loss GB/T 6451 designs. Always compare guaranteed loss tables (no-load W and load W at 75°C) rather than technology labels.

Which transformer is better for a solar farm?

Usually both, at different points in the system: dry-type cast resin units inside the inverter stations for fire safety and low maintenance, and sealed oil-immersed pad-mounted units along the medium-voltage collector circuit for outdoor economy and environmental tolerance.

What is a transformateur sec or transformador seco?

“Transformateur sec” (French) and “transformador seco” (Spanish) both mean dry type transformer — the same epoxy-resin or VPI-insulated, air-cooled unit discussed in this guide. If your project specification uses these terms, request the cast resin product line.

How long does each type last?

With correct loading and maintenance, an oil immersed transformer typically serves 25–30 years, and a cast resin dry type transformer 20–25 years. Insulation temperature is the main life determinant: every 6–8 K of sustained overload above rated temperature roughly halves winding insulation life.

Conclusion: Match the Technology to the Site, Not the Catalogue

There is no universal winner in the dry type vs oil immersed comparison. Indoors and wherever fire safety, proximity to load and low maintenance dominate, choose cast resin. Outdoors, and wherever cost per kVA, overload capability and environmental robustness dominate, choose oil-immersed. On complex sites — solar farms, industrial campuses, mixed-use developments — the most economical design often uses both technologies in the roles they each do best.

Request a Transformer Quotation from Chuanli Electric

IEC 60076-compliant cast resin and oil-immersed transformers, 6–35 kV, 30–2,500 kVA and beyond. Type test reports, efficiency level documentation and export CE certification available on request.

Contact Our Engineering Team

Related Resources

RELATED NEWS
YOU MAY ALSO WANT TO SEE
Get High And Low Voltage Power Transmission And Distribution Solutions Today !
X
icon
icon
icon
en_US