Choosing a ring main unit (RMU) used to come down to price and footprint. Today, the insulation medium — SF6 gas, solid cast resin, or atmospheric air — decides your compliance exposure, your maintenance budget, and sometimes whether a project even clears environmental review. If you are weighing an SF6 vs solid-insulated RMU, or comparing air insulated vs gas insulated RMU options for a 12/24/36 kV network, the differences are larger than most spec sheets admit.
This guide explains how each insulation type works, where it wins, where it costs you, and the eight checks Chuanli Electric’s engineering team runs with EPCs and utility buyers before a single RMU is ordered.
An RMU is a compact, factory-assembled switchboard that connects, protects, and isolates one or more medium-voltage feeders — typically in secondary distribution networks (urban cable rings, industrial plants, commercial buildings, renewable collection points). All three insulation types share the same switching heart: вакуумные прерыватели for load break and fault interruption, plus a switch-fuse or circuit-breaker combination. What changes is the dielectric that fills the gaps around the live parts.
Per IEC 62271-200 (AC switchgear rated above 1 kV up to 52 kV), the insulation medium defines the clearances, the enclosure pressure system, the type-test program, and the maintenance regime. Pick the wrong one and you either overpay for performance you don’t need or under-spec for the environment you actually have. Chuanli Electric manufactures all three families, so this comparison is built from field data — not a catalogue.

Сайт SF6 gas-insulated RMU seals live parts inside a metal enclosure filled with sulfur hexafluoride at low pressure (typically 0.3–0.5 bar gauge). SF6 has excellent dielectric strength, so the tank stays compact even at 36 kV. Chuanli’s XGN43 series SF6 gas-insulated ring main units cover 12/17.5/24/36 kV with vacuum interruption and a sealed pressure system that limits annual leak rate well inside IEC 62271-200 limits.
Where it wins: smallest footprint, sealed against humidity, salt fog and pollution, ideal for dense urban substations and harsh climates where air clearance is hard to guarantee.
Where it hurts: SF6 is a greenhouse gas with a global-warming potential near 24,000× CO₂. Under the EU F-gas Regulation it is being phased down, and several tenders now cap or ban SF6 in new builds. You also need gas-handling discipline and periodic density monitoring.

A solid-insulated RMU — a form of solid insulated switchgear — replaces the gas tank with epoxy-resin cast busbars and embedded vacuum poles. The live conductors are fully encapsulated in solid dielectric, so there is no SF6 to leak and no gas to handle. Chuanli’s CLSR compact solid-insulated ring main unit is built for 12/24 kV indoor and space-constrained installations.
Where it wins: genuinely SF6-free, very low maintenance, and one of the most compact footprints on the market — a strong fit for eco-sensitive projects, indoor rooms, and retrofits where the switch room is already tight.
Where it hurts: the epoxy encapsulation is harder to repair in the field than a bolted air cell, and the upfront cost is typically higher than air-insulated units. End-of-life epoxy recycling is a consideration buyers should raise with the supplier.

Сайт air-insulated RMU uses atmospheric air at ambient pressure as the dielectric, with the larger clearances that implies. Chuanli’s XGN15 fixed-type air-insulated RMU is a proven 12/24/36 kV workhorse, widely used across Chinese distribution networks and export EPC projects.
Where it wins: lowest capital cost, simplest construction, easy visual inspection and field repair, and zero greenhouse-gas medium.
Where it hurts: the larger footprint needs a bigger room, and air clearance is sensitive to humidity, pollution and altitude. In coastal, dusty or high-altitude sites you must either up-rate the IP/creepage or step up to gas or solid insulation.
| Selection Criterion | SF6 Gas-Insulated RMU | RMU с твердой изоляцией | RMU с воздушной изоляцией |
|---|---|---|---|
| Insulation medium | Sealed SF6 gas (~0.3–0.5 bar) | Epoxy-resin solid cast | Atmospheric air |
| Typical voltage | 12 / 17.5 / 24 / 36 kV | 12 / 24 kV | 12 / 24 / 36 kV |
| След | Компактный | Most compact | Largest |
| Upfront cost | Умеренный | Выше | Lowest |
| Техническое обслуживание | Low, but gas monitoring needed | Very low | Higher (cleaning, inspection) |
| Environment | High-GWP gas, F-gas exposure | No GHG, epoxy end-of-life | No GHG |
| Best for | Harsh climates, tight urban rooms | Eco tenders, indoor retrofits | Budget builds, accessible rooms |
Buyers who want SF6-free performance without moving to solid insulation have a third door: eco-gas (SF6-free) RMUs that use a purified natural-origin insulating mixture with near-zero GWP. Chuanli’s CLH 12/24 eco-friendly gas-insulated RMU (SF6-free) keeps the sealed-tank compactness of SF6 while clearing F-gas compliance — the pragmatic middle ground for utilities that still want a gas-tight, weatherproof unit.
If your tender mentions “SF6-free”, “F-gas compliant” or “low-GWP switchgear”, treat an SF6 free ring main unit as a distinct shortlist item rather than assuming any RMU qualifies. Ask the supplier for the gas mixture declaration and the GWP figure in writing.
Before issuing an RFQ, run these eight checks. They are the same ones our engineers use on distribution and renewable projects:
Still deciding between air insulated vs gas insulated RMU? Use the quick decision matrix below — screenshot it for your procurement file.
| If your project is… | Recommended insulation | Why |
|---|---|---|
| Coastal / high-pollution / tight urban room | SF6 or eco-gas | Sealed, weatherproof, compact |
| Eco-tender, indoor retrofit, SF6 banned | Solid-insulated | SF6-free, smallest footprint |
| Budget build, controlled indoor room | Воздушная изоляция | Lowest cost, easy service |
| Future-proofing + F-gas compliance | Eco-gas (SF6-free) | Gas-tight yet low-GWP |
Browse the full ring main unit (RMU) product range to map these checks against certified models and datasheets.
An RMU rarely stands alone. It feeds — and is fed by — medium and high voltage switchgear cabinets such as the KYN28 (12/24 kV) and KYN61 (40.5 kV) metal-clad ranges, plus vacuum circuit breakers and compact substations. Specifying the RMU and the upstream switchgear from one manufacturer keeps the busbar ratings, protection coordination and type-test pedigree consistent — and it is exactly how Chuanli delivered panels for State Grid and major transmission projects.
Need Help Selecting the Right RMU Insulation Type?
Send us your voltage level, load profile and single-line diagram. Our engineers will recommend the most cost-effective RMU configuration — and the certificates to back it — within 24 hours.
Air-insulated RMUs win on upfront price, but SF6 and solid-insulated units often close the gap through lower maintenance and a smaller room. The lowest lifecycle cost depends on your labour rates and space — not the sticker price alone.
SF6 is not globally banned, but the EU F-gas Regulation is phasing it down and some tenders cap or prohibit it in new installations. SF6 RMUs are still widely sold and legal in most markets; just confirm the specific project’s environmental clauses before ordering.
A solid-insulated RMU encapsulates the live conductors in epoxy resin instead of sealing them in SF6 gas. It removes the greenhouse-gas medium and gas-handling entirely, at the cost of a higher purchase price and field-repairability that is more limited than bolted air cells.
Only with care. Air clearance collapses in humidity, pollution, salt fog and at altitude, so air-insulated units need a controlled, often indoor room or a heavily up-rated enclosure. For coastal or dusty sites, gas or solid insulation is the safer default.
At 24 kV, all three work; at 36 kV, gas and solid stay compact while air needs noticeably more space. If the room is tight or the site is harsh, choose SF6/eco-gas or solid. If cost dominates and the room is controlled, air is fine.
Ask for IEC 62271-200 type-test certificates (dielectric, temperature-rise, short-circuit, mechanical endurance, internal-arc where required) and the manufacturer’s routine test records. Chuanli supplies type-test reports and ISO 9001 documentation with every RMU order.
Request a Datasheet & RFQ Package
Get the IEC 62271-200 type-test reports, outline drawings and a configured quote for the RMU insulation type that fits your network — prepared by our engineering team.
Continue the spec with these buyer guides from the Chuanli Electric knowledge base:
Chuanli Electric is a medium- and high-voltage switchgear manufacturer certified to ISO 9001, with products built to IEC 62271 and GB/T standards and supplied to State Grid and major transmission projects including Three Gorges and West-East Power Transmission.